Sale!

Fluidyne V10 V101P4P2A20L Vane Pump | Vickers V10 Replacement 1.3 GPM | 2500 PSI | SAE ‘A’ 2-Bolt | 3/4″ Keyed Shaft

Original price was: $369.92.Current price is: $277.49.

59 in stock

SKU: V101P4P2A20L Category:

Description

For a complete overview of available hydraulic pumps solutions, Northern Hydraulics offers extensive options for every requirement.

Compatibility & Applications

See real-world case studies of single stage vane pumps applications in action across mobile and industrial settings.

Direct Replacement Information

This Fluidyne unit serves as a direct replacement for Vickers V101P4P2A20L in systems requiring 13.1 cm³/r (0.80 in³/r) displacement at pressures up to 2500 PSI..

  • Mounting Pattern: SAE ‘A’ 2-bolt
  • Inlet Port: G1″ BSPP
  • Outlet Port: G1/2″ BSPP

Common Applications

Commonly used in marine applications, stationary power units, test stands.

  • marine applications (see similar applications)
  • stationary power units
  • test stands

Important: Verify pump model V101P4P2A20L matches your existing Vickers unit before ordering. For technical assistance, contact (800) 823-4937.


Purchasing Information

Availability & Delivery

Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.

For current availability on V101P4P2A20L, call (800) 823-4937.

Warranty & Protection

  • 12-month warranty covers manufacturing defects
  • 30-day return window for unopened units
  • Free technical verification before ordering
  • Each pump pressure tested before shipment

Ordering Options

Order online for immediate processing. Phone orders welcome at (800) 823-4937.

Net 30 terms available for approved accounts.

Volume pricing available on orders of 4 or more units.

Support & Documentation

  • Installation guide included with every shipment (see our pumps with integral valves specifications for advanced needs)
  • Technical drawings and specifications available (see our vane pumps documentation hub)
  • Cross-reference guides for common brands, including our Vickers replacement pumps specifications
  • Phone support: Monday-Friday, 7 AM – 5 PM MST

Questions? Call our specialists: (800) 823-4937


Product Selection Guide

These single stage vane pumps are all direct Vickers V10 replacements with identical displacement (0.80 in³/r), flow (4.2 GPM at 1200 RPM), pressure (2500 PSI), and mounting (SAE ‘A’ 2-bolt flange). The key differences between them are shaft type, port position, and rotation direction—each impacting installation compatibility and system design.

?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.

Model Number Flow Rate Max Pressure Displacement Mounting
V101P4P2A20L (Current) 4.2 GPM 2500 PSI 13.1 cm³/r (0.80 in³/r) 2-Bolt Flange (SAE “A” size)
V101P4P11A20L (similar specs) 4.2 GPM 2500 PSI 13.1 cm³/r (0.80 in³/r) 2-Bolt Flange (SAE “A” size)
V101P4P11A20R 4.2 GPM 2500 PSI 13.1 cm³/r (0.80 in³/r) 2-Bolt Flange (SAE “A” size)
V101P4P11C20L 4.2 GPM 2500 PSI 13.1 cm³/r (0.80 in³/r) 2-Bolt Flange (SAE “A” size)
V101P4P11C20R 4.2 GPM 2500 PSI 13.1 cm³/r (0.80 in³/r) 2-Bolt Flange (SAE “A” size)

Key Differences

Shaft Type

Difference: V101P4P2A20L uses a straight keyed shaft, while the other models (V101P4P11A20L, V101P4P11A20R, V101P4P11C20L, V101P4P11C20R) use a 9-tooth splined shaft.

Selection Guide: Choose a straight keyed shaft for standard couplings and lower torque needs; select a splined shaft for high-torque or precision alignment applications.

Port Position

Difference: V101P4P2A20L, V101P4P11A20L, and V101P4P11A20R have ports opposite from inlet (180°), while V101P4P11C20L and V101P4P11C20R have ports inline with the inlet (0°).

Selection Guide: Choose 180° port position for installations needing opposite-facing connections; choose 0° (inline) for straight-through plumbing or to match existing system layouts.

Rotation Direction

Difference: L-suffix models (V101P4P2A20L, V101P4P11A20L, V101P4P11C20L) are left-hand (counter-clockwise), R-suffix models (V101P4P11A20R, V101P4P11C20R) are right-hand (clockwise) rotation.

Selection Guide: Match rotation to your system’s prime mover: use left-hand (L) for counter-clockwise drive shafts, right-hand (R) for clockwise.

Quick Selection Guide

If you need: Standard keyed shaft, 180° port position, left-hand (CCW) rotation

Choose: V101P4P2A20L

Because: Ideal for most Vickers V10 replacements with common shaft coupling and standard port orientation.

If you need: Splined shaft, 180° port position, left-hand (CCW) rotation

Choose: V101P4P11A20L

Because: Offers higher torque transmission with the same port layout as the keyed version.

If you need: Splined shaft, 180° port position, right-hand (CW) rotation

Choose: V101P4P11A20R

Because: For clockwise-driven applications requiring splined shaft and opposite port configuration.

If you need: Splined shaft, inline (0°) port position, left-hand (CCW) rotation

Choose: V101P4P11C20L

Because: Matches installations where straight-through port alignment is required and the drive is counter-clockwise.

If you need: Splined shaft, inline (0°) port position, right-hand (CW) rotation

Choose: V101P4P11C20R

Because: Best for systems needing straight port alignment with a clockwise drive.

Compatibility: All models are 100% compatible with Vickers replacement pumps—sharing SAE ‘A’ mounting, displacement, flow, and port sizes for seamless drop-in replacement.

For help choosing the best model for your application, Northern Hydraulics hydraulic specialists can recommend compatible vane pumps are available at (800) 823-4937 applications, Mon-Fri, 7 AM – 5 PM MST. For a full range of hydraulic pumps, explore our main product family.